Error during check Phase in SUM


Hello All.

 

I am applying EHP3 upgrade on CRM installation.

 

During Check phase I get this error: The error is but BW consistency, but my system is a CRM system:

 

 

 

ACTIVATION CHECK ERRORS and RETURN CODE in RSUPGRCHECK.PC1

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

4 ER7000 "Check for DDIC Consistency of BW Objects" " " " " " "

4 ER7000 "InfoObjects Check" " " " " " "

4 ER7000 "Activate all Dictionary objects ( 255 ):" " " " " " "

4 ER7854 All DDIC objects have been activated / deleted

2EER7000 "InfoObject 0RSPL_ORG is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSPL_ORG": "VIEW" "/BI0/6RSPL_ORG" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_EID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_EID": "VIEW" "/BI0/7RSTT_EID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_IONM is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_IONM": "VIEW" "/BI0/7RSTT_IONM" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_IPNM is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_IPNM": "VIEW" "/BI0/7RSTT_IPNM" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_JID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_JID": "VIEW" "/BI0/7RSTT_JID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_LGUID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_LGUID": "VIEW" "/BI0/7RSTT_LGUID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_OBJNM is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_OBJNM": "VIEW" "/BI0/7RSTT_OBJNM" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_PID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_PID": "VIEW" "/BI0/7RSTT_PID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_PVAR is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_PVAR": "VIEW" "/BI0/7RSTT_PVAR" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_QYNM is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_QYNM": "VIEW" "/BI0/7RSTT_QYNM" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_RQID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_RQID": "VIEW" "/BI0/7RSTT_RQID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_SVARI is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_SVARI": "VIEW" "/BI0/7RSTT_SVARI" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_TID is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_TID": "VIEW" "/BI0/7RSTT_TID" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_TONAM is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_TONAM": "VIEW" "/BI0/7RSTT_TONAM" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_TRANR is not" "consistent. Activate it." " " " "

3WER7030 InfoObject "0RSTT_TRANR": "VIEW" "/BI0/7RSTT_TRANR" is not active - activating InfoObject now

2EER7000 "InfoObject 0RSTT_USER is not" "consistent. Activate it." " " " "

 

Thanks for any help

 